    waldi (waldi@chaos.social)'s status on Wednesday, 01-Jan-2025 22:55:50 JSTwaldiwaldi
    in reply to
    • Jan Wildeboer 😷:krulorange:

    @jwildeboer The relevant data sheet lines are: MPP voltage and operating voltage. The inverter input needs to be able to handle the voltage provided by the panel. And if you chain two panels, you need to sum up those voltages.

    Example:

    VertexS 400Wp module:
    VMPP: 34,2V
    VOC: 41,2V

    Enphase IQ8M inverter:
    Operating range: 16-56V

    This combination can clearly not handle two such panels on one input.